Description
English: The workflow for a typical cryo-EM experiment can be divided into several stages, including sample preparation, grid preparation, data collection, image processing, and structure determination. Here is a brief overview of each stage:

1. Sample preparation: This involves purifying the biological sample of interest, such as a protein, protein complex, virus, or cell. The sample must be in a purified and homogeneous state, free of contaminants and aggregates. Depending on the sample, various techniques such as size-exclusion chromatography, affinity chromatography, or ultracentrifugation may be used for purification.

2. Grid preparation: The purified sample is then applied to a special type of electron microscopy grid, typically made of carbon or gold. The grid is first treated with a thin layer of a hydrophilic polymer to prevent the sample from sticking to the grid. The sample is then applied to the grid, and excess buffer is blotted away. The grid is then rapidly frozen in liquid ethane or propane to create a thin layer of vitrified ice around the sample.

3. Data collection: The frozen grids are loaded into a cryo-electron microscope, and images are collected using an electron beam. The microscope can be operated in either automated or manual modes. In automated mode, the microscope software automatically selects grids and acquires images from different areas on the grid. In manual mode, the user manually selects regions of interest on the grid for imaging. Typically, hundreds to thousands of images are collected from different angles, which are used for further processing.

4. Image processing: The collected images are processed to improve their quality and to generate a 3D reconstruction of the sample. This involves several steps, including particle picking, 2D classification, averaging, and refinement. In particle picking, individual particles in the images are identified and extracted. In 2D classification, the particles are sorted into different classes based on their orientations and similarities.

5. In 3D reconstruction, the sorted particles are used to generate a 3D density map of the sample.

6. Model building and refinement: Once the 3D map is obtained, a structural model of the protein or complex can be built using computational methods. The model is refined iteratively by comparing it to the cryo-EM map and making adjustments until a high-quality model is obtained.

the structural model can be analyzed to gain insights into the structure and function of the protein or complex, such as understanding how it interacts with other molecules or how it catalyzes chemical reactions.
This file was uploaded as part of a research data project at Leeds University Library.

This tag does not indicate the copyright status of the attached work. A normal copyright tag is still required. See Commons:Licensing.

institution QS:P195,Q24568958

Date
Source Own work
Author

Hiramano92

Incorporates these images:

Other versions

Licensing

I, the copyright holder of this work, hereby publish it under the following license:
w:en:Creative Commons
attribution share alike
This file is licensed under the Creative Commons Attribution-Share Alike 4.0 International license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
  • share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.

Captions

Workflow of how to obtain 3D model of biological samples using Cryo-EM

29 March 2023

image/svg+xml

8f07f55ade28c3fec9776aab10ef1b96acbede74

1,285,529 byte

384 pixel

512 pixel

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current14:43, 29 March 2023Thumbnail for version as of 14:43, 29 March 2023512 × 384 (1.23 MB)Hiramano92Uploaded own work with UploadWizard
The following pages on the English Wikipedia use this file (pages on other projects are not listed):

Global file usage

The following other wikis use this file:

Metadata