GWR standard boiler types[1]
Type Introduced Front dia Rear dia Length Firebox len Pressure range Used by
1 1903 4 ft 11 in (1.499 m) 5 ft 6 in (1.676 m) 14 ft 10 in (4.521 m) 9 ft 0 in (2.743 m) 200–225 psi (1.38–1.55 MPa) Saint, 2800 & 2884, Star, Hall & Modified Hall and Grange classes
2 1903 4 ft 5 in (1.346 m) 5 ft 0 in (1.524 m) 11 ft 0 in (3.353 m) 7 ft 0 in (2.134 m) 195–200 psi (1.34–1.38 MPa) Aberdare, Bulldog & Bird, County Tank, 5600, 3100 (1903), 5101, 6100 and 8100 classes
3 1903 4 ft 5 in (1.346 m) 5 ft 0 in (1.524 m) 10 ft 3 in (3.124 m) 7 ft 0 in (2.134 m) 195–200 psi (1.34–1.38 MPa) Bulldog & Bird and 3600 'Birdcage' classes
4 1902 4 ft 11 in (1.499 m) 5 ft 6 in (1.676 m) 11 ft 0 in (3.353 m) 7 ft 0 in (2.134 m) 195–200 psi (1.34–1.38 MPa) City, Churchward County, 3150, 4200, 4300 'Mogul', 5205, 7200 and 3100 (1938) classes
5 1904 4 ft 2 in (1.270 m) 4 ft 9 in (1.448 m) 10 ft 6 in (3.200 m) 5 ft 10 in (1.778 m) 165–200 psi (1.14–1.38 MPa) 4400, 4500 & 4575 and 4600 classes
6 1908 5 ft 6 in (1.676 m) 6 ft 0 in (1.829 m) 23 ft 0 in (7.010 m) 8 ft 0 in (2.438 m) 225 psi (1.55 MPa) 111 The Great Bear
7 1921 5 ft 6 in (1.676 m) 6 ft 0 in (1.829 m) 14 ft 10 in (4.521 m) 10 ft 0 in (3.048 m) 225 psi (1.55 MPa) 4700 class
8 1923 5 ft 2 in (1.575 m) 5 ft 9 in (1.753 m) 14 ft 10 in (4.521 m) 10 ft 0 in (3.048 m) 225 psi (1.55 MPa) Castle class
9 1924 4 ft 4 in (1.321 m) 4 ft 5 in (1.346 m) 10 ft 3 in (3.124 m) 6 ft 6 in (1.981 m) 150–165 psi (1.03–1.14 MPa) Absorbed locos
10 1924 4 ft 5 in (1.346 m) 5 ft 4 in (1.626 m) 10 ft 3 in (3.124 m) 6 ft (1.829 m) 150–200 psi (1.03–1.38 MPa) 2251, 9400 and 1500 classes
11 1924 4 ft 2 in (1.270 m) 4 ft 3 in (1.295 m) 10 ft 6 in (3.200 m) 5 ft 6 in (1.676 m) 150–165 psi (1.03–1.14 MPa) Absorbed locos
12 1927 5 ft 6 in (1.676 m) 6 ft (1.829 m) 16 ft (4.877 m) 11 ft 6 in (3.505 m) 250 psi (1.72 MPa) King class
14 1938 4 ft 8 in (1.422 m) 5 ft 3 in (1.600 m) 12 ft 6 in (3.810 m) 8 ft 8 in (2.642 m) 225 psi (1.55 MPa) Manor class
15 1945 5 ft (1.524 m) 5 ft 8 in (1.727 m) 12 ft 7 in (3.835 m) 9 ft 9 in (2.972 m) 280 psi (1.93 MPa) Hawksworth County class
16 1949 3 ft 9 in (1.143 m) 3 ft 10 in (1.168 m) 10 ft 1 in (3.073 m) 5 ft (1.524 m) 165 psi (1.14 MPa) 1600 class
21 1931 4 ft 2 in (1.270 m) 4 ft 3 in (1.295 m) 10 ft 6 in (3.200 m) 5 ft 6 in (1.676 m) 165–180 psi (1.14–1.24 MPa) 5400 and 6400 classes

Notes[edit]

  1. ^ Griffiths 1987, p. 147.

References[edit]

  • Griffiths, Denis (1987). Locomotive engineers of the GWR. Wellingborough: Stephens. ISBN 0850598192.